Latest News
Armorgard 507
CLEAR FLOORING SYSTEM
- PRIMERLESS
- 100 % SOLIDS
- USDA APPROVED
- ENVIRONMENTALLY FRIENDLY
- CHEMICALLY RESISTANT
- BONDS TO DAMP CONCRETE
Copps Armorgard 507 is a 100 % solids, self leveling, primerless, odorless, clear epoxy flooring system designed to resurface concrete. Armorgard 507 has excellent resistance to most harsh chemicals and can be applied as thin as 10 mil. Armorgard 507 is USDA approved for application to structural surfaces or surfaces that will receive incidental food contact. Adhesion to wood, concrete and most metals is excellent. Armorgard 507 can be used as a clear coating or filled with a colored aggregate to produce a colored/clear topping.
Armorgard 507 was designed to protect floors from light to medium traffic found in power plants, chemical processing, pulp and paper mills, the food and beverage industry, and anywhere a clean, attractive appearance is desired.
Application thickness can be varied from a 10 mil rolled coat (unfilled) to a 1/8" colored broadcast resurfacer.
PACKAGING CONVENIENCE
Armorgard 507 is conveniently packaged in pre-measured 1.5 or 4 gallon kits containing a resin (Part A) and a hardener (Part B). Larger bulk quantities are also available.
| COMPONENTS | Resin/Hardener/Colored Aggregate (optional) | |
|---|---|---|
| COLOR | Clear/colored aggregates: Grey, Red, Natural-Buff |
|
| MIXED VISCOSITY, cP | 600 | ASTM D 2196 |
| WORKING TIME, min | 25 | |
| GEL TIME, min | 30 | |
| TACK-FREE TIME, h | 5 - 6 | |
| INITIAL CURE or FOOT TRAFFIC TIME, h | 9 - 12 | |
| COVERAGE* @10 mil (unfilled), ft2/gal | ||
| APPLICATION TEMPERATURE, °F | ||
| Ideal | 70 - 80 | |
| Acceptable | 55 - 90 | |
* Varies with porosity of concrete
| HARDNESS, Shore D | 82 | ASTM D 2240 |
|---|---|---|
| ADHESION TO CONCRETE, psi | > 800 (100 % failure in concrete) | ASTM D 4541 |
| COMPRESSIVE STRENGTH, psi | 12,000 | ASTM D 695 |
| TENSILE STRENGTH, psi | 6,100 | ASTM D 638 |
| ELONGATION @ BREAK, % | 6 | ASTM D 638 |
| FLEXURAL STRENGTH, psi | 10,000 | ASTM D 790 |
| LINEAR SHRINKAGE | 0.0006 | ASTM D 2566 |
HUMIDITY/DEW POINT
Relative humidity and dew point must be determined before application to avoid adhesion failures. The dew point is used to predict the substrate temperature at which moisture begins to condense, in the form of water, on the substrate. Never apply a coating unless the concrete surface temperature is 5 °F above the dew point. This temperature difference must be observed until the epoxy coating is cured to a tack-free state. A dew point calculation chart is available from a Copps Technical Representative.
| Excellent Resistance | Very Good | Not Recommended | |
|---|---|---|---|
| Motor Oil | 10 % Nitric Acid | 20 % Acetic Acid | > 50 % Acetic Acid |
| Unleaded Gasoline | 10 % Sulfuric Acid | 1,1,1-Trichloroethane | > 50 % Nitric Acid |
| Kerosene | 80 % Sulfuric Acid | Xylene | Methylene Chloride |
| Diesel Fuel | 50 % Sodium Hydroxide | Methyl Ethyl Ketone | |
| Ethylene Glycol | 10 % Hydrochloric Acid | Toluene | |
| Water | 36 % Hydrochloric Acid | Acetone | |
| 10 % Lactic Acid | Skydrol | Ethyl Alcohol | |
| 10-30 % Citric Acid | Bleach | Methyl Alcohol | |
| 10 % Acetic Acid | Cyclohexanol | ||
| 50 % Phosphoric Acid | |||
SURFACE PREPARATION
Armorgard 507 is used to strengthen and seal a porous concrete substrate, therefore, adhesion is paramount. To achieve excellent adhesion, the substrate should be free of all loose and foreign material and should be roughened slightly to provide a coarse profile by either shot blasting or acid etching.
Before blasting or acid etching, any contaminates on/in the concrete must be identified. Oils, grease, fats, waxes or other contaminates must be removed prior to roughening the concrete. These can be removed with an application of warm (120-140 °F) caustic detergent, steam cleaning or pressure washing. De-grease the floor, follow with a hot water rinse.
Repeat this procedure until the water does not "bead up" on the concrete.
Shot blasting using self-propelled, self-contained equipment is a highly recommended preparation method.
Acid etching can be performed using a solution of 50 % muriatic (Hydrochloric) acid and 50 % water. (Always add acid to water slowly when mixing). The acid solution should be carefully applied to all surfaces to be coated. The acid will effervesce (foam or bubble) on the concrete if it is free of a sealer or contaminate. If the acid does not effervesce, contact a Copps representative immediately. Do not apply the epoxy. Leave the acid on the concrete for 10-15 minutes then rinse the entire area well with cold water. We recommend a surface profile similar to 60-100 grit sandpaper. If the profile is not sufficient – repeat the procedure. When the profile is sufficient, vacuum up all standing water and allow the surface to dry. Muriatic acid can be dangerous to handle, so proper safety equipment/ventilation should be used. Do not allow the acid wash to enter any drains or sewers.
NEW CONCRETE MUST CURE A MINIMUM OF 28 DAYS PRIOR TO THE APPLICATION OF ANY EPOXY.
MIXING
To mix Armorgard 507 pour the contents of the pail marked Hardener (B-507) into the larger Resin pail. Immediately mix for 3 minutes (or until uniform) using a Jiffy Mixer and a slow speed drill. Mix at slow speed (less than 850 rpm) to avoid air entrainment. DO NOT mix more material than can be used within the stated working time.
REMEMBER - you will have less working time at higher temperatures.
APPLICATION
PRIMER
1.) The application of a primer is recommended to reduce concrete outgassing, in turn producing a smoother coating.
2.) Armorgard 507 can be applied to prepared concrete without a primer.
Apply with a squeegee and a medium (3/8" nap) roller.
PRIMER MIXING
To mix Copps K-040 concrete primer pour the contents of the can marked Hardener (B-025) into the large pail (resin). Immediately mix for 3 minutes (or until uniform) using a Jiffy Mixer and a slow speed drill. Mix at slow speed (less than 850 rpm) to avoid air entrainment.
PRIMER APPLICATION
Apply 5 mil of Copps K-040 Concrete Primer to the prepared concrete with a short nap (1/4") roller. This insures adhesion to the concrete substrate.
DO NOT apply K-040 over standing water. Damp or dry concrete is acceptable.
LIGHT "ROLLED" ARMORGARD 507 COAT FOR LIGHT DUTY - 10-30 mil liquids only
Apply with a squeegee and a medium (3/8") nap roller.
MEDIUM DUTY "BROADCAST" COATING - 30-60 mil
Apply liquid 15-30 mil thick then evenly broadcast colored aggregate into the wet coating until it is saturated. Let cure (dry), then brush off the excess aggregate and apply a 5-10 mil liquids only topcoat to lock down the exposed aggregate. Repeat as needed to achieve your desired texture.
CLEAN UP
Armorgard 507, before it has hardened, can be removed from tools with Copps Enviro Kleen solvent.
SAFETY PRECAUTIONS
Avoid breathing of vapors. Forced local exhaust is recommended to effectively minimize exposure. NIOSH approved, organic vapor respirators and forced exhaust are recommended in confined areas, or when conditions (such as heated polymer, sanding) may cause high vapor concentrations. Do not weld on, burn or torch any epoxy material. Hazardous vapor is released when an epoxy is burned.
Avoid skin or eye contact. Wash skin with soap and water is contact occurs. If eye contact occurs flush with water for 15 minutes and obtain medical attention.
Read and understand all cautions on can labels and material safety data sheets before using this material.
WARRANTY AND DISCLAIMER
Copps Industries, Inc. gives no warranty, express or implied, and all products are sold upon condition that purchasers will make their own tests to determine the quality and suitability of the product. Copps Industries, Inc. shall be in no way responsible for the proper use and service of the product. The information given in this publication is considered to be accurate and reliable and is provided as a service only. Physical properties shown are typical. Actual properties are dependent on curing conditions and degree of cure. Any information or suggestions given are without warranty of any kind and purchasers are solely responsible for any loss arising from the use of such information or suggestions. No information or suggestions given by us shall be deemed to be a recommendation to use any product in conflict with any existing patent rights.
TB#4507 (11/25/02)
Concrete Coatings and Joint Filler
- Armorgard 500
- Armorgard 501
- Armorgard 502
- Armorgard 506
- Armorgard 507
- Armorgard 700
- Armorgard 700UV
- Armorgard 600T
- Armorgard 601T
- Armorgard 602T
- Armorgard 604T
- Armorgard 600SF
- Armorgard 601SF
- Epoxy Primer (K-049)
- Epoxy Primer (K-040)
- FlexFill 60 Joint Filler (K-057)
- FlexFill 90 Joint Filler (K-560)
- K-561 Non Haz Joint Filler
- Floor Patch (K-002)
- Armorgard 295