K-561 Non Haz Joint Filler

SEMI-RIGID EPOXY JOINT FILLER FOR CONTROL JOINTS OR CONTRACTION JOINTS

Flexfill Non-Haz has been developed to replace existing joint filler formulations which use corrosive materials requiring more stringent shipping and handling procedures. Formulated specifically for filling sawcut control joints and contraction joints in concrete, Flexfill Non-Haz is a low viscosity liquid which cures to a semi-rigid, hard-rubber-like resiliency for supporting joint edges in order to prevent deterioration and spalling. Flexfill Non-Haz joint filler bonds tightly to the sides of concrete joints, prevents contaminant and water penetration, and delivers high wear resistance and durability.

FLEXFILL NON-HAZ JOINT FILLER FEATURES

  • DOT NON-HAZARDOUS
  • FAST 4 HOUR SHAVE TIME
  • IDEAL 1:1 MIX RATIO
  • VOC FREE, 100% SOLIDS
  • BONDS TO MOST CONSTRUCTION MATERIALS
  • EASILY COATED WITH COMPATIBLE TOPPINGS
  • THIXOTROPIC JOINT FILLER CONSISTENCY – DESIGNED TO REDUCE JOINT FILLER “SINKERS” SAVING TIME AND MONEY
PRODUCT DESCRIPTION AND CHARACTERISTICS
TWO PART EPOXY, THERMOSETTING RESIN
MIX RATIO BY VOLUME 1:1
COLOR light grey
WORKLIFE, AFTER MIXING RESIN & HARDENER 10-12 min. @ 72°F
APPLICATION THICKNESS 1/8" or greater
SHAVE TIME 4 hours @ 72°F
CURING TIME 24 hours @ 72°F
TENSILE STRENGTH (ASTM D-638) 500 psi
% TENSILE ELONGATION 20
HARDNESS (SHORE A) (ASTM D-2240) 91A
MIXED VISCOSITY @ 77°F (ASTM D-2196) 4000 cPs

PACKAGING

K-561-20 (2 gallon) PREMEASURED KIT = 448 in.3
K-561-100 (10 gallon)PREMEASURED KIT = 2243 in.3
BULK 55 GALLON DRUMS AVAILABLE

WHAT TYPE OF JOINT ARE YOU FILLING?

TYPE 1TYPE 2
USE FLEXFILL NON-HAZ HEREDO NOT USE FLEXFILL NON-HAZ HERE
Names * Control joint
Contraction joint
Non-working joint
Names * Expansion joint
Isolation joint
Working joint
Characteristics No movement or negligible movement
Sawcut
Characteristics Significant movement
Formed

* Name distinctions are based on American Concrete Institute, ACI 504R-90

APPLICATION INSTRUCTIONS

WHEN TO INSTALL FLEXFILL NON-HAZ

Flexfill Non-Haz should not be installed on "green" concrete. A minimum 30-day concrete cure is required. 90-120 days is ideal. The ideal time to install is when the area is at its long term, stable temperature.

JOINT OR CRACK APPLICATION

Any loose concrete, previous joint compound or other materials must be removed to leave a clean, sound joint. All dirt, oil, sealers or chemical residue must be removed. To achieve optimum performance the joint should be sawcut, and/or chipped to leave a clean, dry surface for bonding. Prepared joint depth should be at least (minimum) two (2) times the width. Wire brush joint sides to remove laitance. Bond breaker must be used. Use of a 1/4" layer of 30-60 mesh dry silica sand in bottom of joint is recommended. The bond breaker is designed to prevent three-sided adhesion of the epoxy. Adhesion to the joint walls is the only adhesion desired. DO NOT USE A BACKER ROD. A backer rod does not produce a stable, long term load transfer.

APPLICATION

Do not rapidly change the temperature of the air/concrete before installing Flexfill Non-Haz. Keep the temperature constant, same as long term temperature. Floor temperature must be between 60 - 90 °F (15.5 - 32.2 °C) during application for complete cure. Temperatures below 50 °F (10 °C) will inhibit the cure resulting in a sticky surface. The liquid material should be stored at 60-90 °F prior to installation.

MIXING

Mix the Resin (Part A) and the Hardener (Part B) for 2-3 minutes with a slow speed (850 rpm or less) drill and Jiffy Mixer (mixing paddle). Pour the material into the joint. If a flush joint is desired slightly overfill the joint and let cure, then use a floor scraper or knife-edge to cut the material flush with the concrete. If you need less than a full kit, do not “eyeball” the mixture. Accurately measure the resin and hardener following the mixing ratios under “PRODUCT DESCRIPTION AND CHARACTERISTICS.”
Flexfill Non-Haz has a work life of 10-12 minutes at 72 °F (22 °C), and can be applied as thickly as needed in one coat. If it is necessary to bond Flexfill Non-Haz to itself, abrade the old material before pouring new material.

CLEAN UP

Flexfill Non-Haz, before it has fully cured, may be removed from tools with Copps Enviro-Kleen solvent or isopropyl alcohol.

SAFETY

Flexfill Non-Haz is an epoxy resin system. Please refer to Material Safety Data Sheets before using this product. DO NOT WELD ON, BURN OR TORCH ON OR NEAR ANY EPOXY MATERIAL.

EXPLANATION OF PRODUCT CHARACTERISTICS AND PHYSICAL PROPERTIES

Important product characteristics include tensile strength, percentage tensile elongation and Shore A hardness.

  • These characteristics relate to Flexfill Non-Haz after it has completely cured.
  • In simple terms:
    • Tensile strength relates to the capacity of this material to hold together when stretched.
    • Percentage tensile elongation is the length the material can be stretched before failure.
    • Shore A hardness relates to a standard for “hardness – softness” so that different materials may be measured against the same reference point.

Flexfill Non-Haz has been designed to function as a joint filler. It must stretch or give to allow for expansion or contraction within the concrete slab. At the same time it must deliver adequate support to joint shoulders receiving the force of hard wheel traffic carrying heavy loads. It must bond to joint sides to provide a seal to prevent contaminant entry and its surface texture must deliver sufficient wear capacity. Extensive tests and use of Flexfill Non-Haz demonstrate these capacities.

WARRANTY AND DISCLAIMER

Copps Industries, Inc. gives no warranty, express or implied, and all products are sold upon condition that purchasers will make their own tests to determine the quality and suitability of the product. Copps Industries, Inc. shall be in no way responsible for the proper use and service of the product. The information given in this publication is considered accurate and reliable and is provided as a service only. Physical properties shown are typical. Actual properties are dependent on curing conditions and degree of cure. Any information or suggestions given are without warranty of any kind and purchasers are solely responsible for any loss arising from the use of such information or suggestions. No information or suggestions given by us shall be deemed a recommendation to use any product in conflict with any existing patent rights.

TB#4561 (07/17/08)